Ships in 3 to 5 Business Days
Ships in 3 to 5 Business Days
The Domus 3 Alternating Pressure Redistribution System by Wellell offers significant benefits for patients at moderate to high risk of pressure injuries. By combining alternating pressure redistribution and static therapy modes, it ensures continuous and effective pressure relief, reducing the risk of developing pressure injuries. The system’s ability to adjust pressure firmness based on the patient’s weight distribution promotes optimal comfort and support, enhancing overall patient well-being. This mattress system can carry up to 440lbs capacity and with 20 cells and have a

The Domus 3 Alternating Pressure Redistribution System helps keep patients comfortable by combining alternating and static therapy to relieve pressure and reduce the risk of pressure injuries. It features a low-pressure alert to ensure patient safety and a weight indicator dial for easy adjustment to match the patient’s needs. The system also wicks away moisture, helping to keep the skin dry and comfortable while maintaining firm support. This all leads to better comfort, skin protection, and a reduced risk of pressure injuries for the patient.

The Domus 3 features micro low air loss technology that effectively wicks away moisture from the surface, promoting a more comfortable experience for the patient. This helps maintain optimal skin dryness, reducing the risk of skin irritation and pressure injuries while enhancing overall comfort.

Unplugging the quick connector on the Domus 3 bed mattress automatically switches it to constant pressure mode, making it easier to transport. This feature ensures that the mattress remains stable and secure during movement, enhancing convenience for caregivers and patients alike.

The Domus 3 mattress features a nylon and polyurethane (PU) cover that is vapor-permeable and water-resistant. This cover also has basic flame-retardant properties, providing added safety and comfort for patients. Its design helps maintain a dry environment while ensuring durability and protection.

Foam Base Pocket
Foam base pocket located under the mattress allows caregivers to insert additional foam to improve stability.
Top Cover
The top cover is made with welded seams (high frequency induction hardening®) to avoid fluid ingression.
Dual Therapy Mode
Provide Static mode for enhanced patient immersion, Alternate mode for allowing pressure redistribution.
Prioritize Patient Safety
Visual signals are used to provide low-pressure alarms to alert caregivers in case of failure.
Important Notice: Due to health and hygiene regulations, this product is non-returnable. We recommend verifying the dimensions and specifications before purchase to ensure it meets your needs.
Wellell Domus 3 Product Brochure
| Mattress | |
|---|---|
| Maximum Patient Weight | 440 lb |
| Length | 79" |
| Width | 35" |
| Height | 8" |
| Type | 8" Replacement |
| Weight | 15.2 lb |
| Top Cover Material | Nylon / PU with Cotton Fabric |
| Cell Material | Nylon / PVC |
| Dimension (Cells) | 20 |
| Pump | |
| Dimension | 11.4" x 7.3" x 5" |
| Weight | 5.1 lb |
| Case Material | Fire Retardant ABS |
| Supply Voltage | 120 V / 60 Hz |
| Therapy Mode | Alternate / Static |
| Noise Level | < 35dB |
Once your order is placed, you will receive an order confirmation email confirming that we have received and begun processing your order.
Stock availability is confirmed after purchase:
In stock: Your order will be prepared and shipped.
Out of stock/backorder: We will contact you with available options, which may include an estimated restock date, an alternative product, or a refund if you choose not to proceed.
You will receive email updates throughout the process, including tracking details once your order ships.
Cancellations within 24 hours may be approved at our discretion only if the order has not been placed/paid with the supplier or shipped.
Returns are accepted within 7 days of delivery for most products. All approved refunds are subject to a 25% restocking fee, and all shipping and any white-glove delivery costs are non-refundable.
After 7 days, and up to 14 days from delivery, eligible orders may be exchanged only, subject to the same condition requirements.
Certain products, including pre-orders, backorders, custom items, and select brands, are final sale and not eligible for return, refund, or exchange. After 14 days from delivery, all sales are final.
Returned items must be unused, in their original packaging, and include all accessories, components, and documentation. Return shipping costs are the customer’s responsibility and are non-refundable.
All return, refund, or exchange requests must be submitted in writing to
📧 support@firstclassmobility.com
Pre-orders and backorders are paid in full at the time of purchase to secure inventory that is specifically allocated to your order.
Once placed, we immediately commit funds with our suppliers and reserve inventory. For this reason, pre-orders and backorders cannot be cancelled and are non-refundable once confirmed.
Estimated shipping timelines are provided in good faith. Delays may occur due to factors outside our control, including manufacturing schedules, supplier availability, or freight and logistics issues.
If an exception is approved at our sole discretion, a cancellation and restocking fee will apply and will be deducted from any approved refund.
The following categories are non-returnable and non-refundable:
Beds and mattresses
Batteries and chargers
All lifts (residential, vehicle, and patient lifts)
Lift chairs, geri chairs, and patient room chairs
Wheelchair cushions, support surfaces, and slings
Mobility accessories
Red light therapy devices
All products sold under the brand Discover Your Mobility
View the full list of non-returnable brands here .
If an item arrives defective or damaged, the manufacturer will offer a replacement at no cost. Issues must be reported within 24 hours of delivery.
A replacement requires the defective item to be returned before a new unit is shipped. A prepaid return label will be provided for approved claims.
If you decline a replacement and request a return instead, the request will be handled under the standard return policy, including a 25% restocking fee and non-refundable shipping costs.
Damage not reported within 24 hours may not be eligible for a claim.
Large or freight items are delivered to the address provided at checkout and are typically not returned to sender. Tracking details will be provided.
If an order is refused at delivery or returned to the sender, a 25% restocking fee will apply, and you are responsible for all outbound and return shipping costs.
All products are covered by the manufacturer’s warranty, which varies by brand.
We can provide proof of purchase and assist with documentation; however, warranty claims are handled directly by the manufacturer.
After the return period, repair or replacement decisions are subject to the manufacturer’s warranty terms and may require return of the defective item.
If you experience any issues with your order, please contact us first so we can assist.
By placing an order, you acknowledge and agree to this policy. In the event of a payment dispute or chargeback, this policy and supporting documentation may be provided to your financial institution for review.
By placing an order with FirstClassMobility.com, you confirm that you have read, understood, and agree to this policy, including applicable restocking fees, shipping costs, and final sale exclusions.
All product specifications are provided by the manufacturer as a general guide. Actual measurements and performance may vary due to manufacturing tolerances, optional accessories, or product updates.
{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}