Skip to content

Save $100 on All Orders Over $1000! Use Code: MOBILITY100 at Checkout.

Free Shipping Within the 48 Contiguous States. (exclusions may apply)

Wellell Optima Optima Prone Position Alternating Mattress

SKU PD09502
by Wellell
Save 33% Save 33%
Original price $10,650.00
Original price $10,650.00 - Original price $10,650.00
Original price $10,650.00
Current price $7,100.00
$7,100.00 - $7,100.00
Current price $7,100.00

1 year warranty


Lowest Prices Guaranteed

Free Shipping US

No Sales Tax


Secure Payments

Automatic Turning Pressure Relief Mattress That Keeps Support Moving Through the Night

The Wellell Optima Turn is a prone positioning pressure relief system designed for users at high to very high risk who require regular repositioning and consistent pressure care. It supports one of the most demanding parts of care—turning and upper body positioning by combining automatic lateral rotation with a built-in shoulder lifting mode.

Instead of relying on multiple caregivers to lift, turn, and reposition the upper body, the mattress helps manage this automatically. It reduces physical strain, supports safer head and airway positioning, and maintains pressure relief throughout the day and night without constant manual handling.

Key Features

  • Automatic 30° lateral turning through the night
  • Helps reduce manual repositioning
  • Adjustable operating cycles from 10 to 25 minutes
  • Supports users up to 397 lbs
  • Side bolsters for safer positioning during turning
  • Heel relief zones for vulnerable pressure points
  • Moisture management for a drier surface
  • Low-pressure alerts for added caregiver reassurance

Designed for Home Care That Needs Less Lifting

The Optima Turn is a lateral rotation pressure relief mattress for users who need regular repositioning and more consistent pressure care at home. Instead of depending on the caregiver to manage every turn manually, the mattress handles gentle side-to-side turning automatically, helping maintain better positioning over time.

Automatic Rotation That Continues Overnight

One of the biggest callouts on the Optima Turn is its ability to keep turning support active through the night. The mattress rotates the user up to 30° at adjustable intervals, helping relieve pressure from the same contact points without repeated waking and manual repositioning.

Side Bolsters for Safer, More Stable Positioning

Firm TPU side bolsters along both sides of the mattress help keep the user positioned more securely during turning. This helps reduce pressure against bed rails and supports a safer, more stable surface during repositioning.

Heel Relief for High-Risk Pressure Areas

Individual heel air cells can deflate to create a lower-pressure zone around the heels. This targeted offloading helps protect one of the most vulnerable areas of the body during longer periods in bed.

Support for Bony Areas During Repositioning

Mechanically assisted turning helps reduce the need for repositioning pillows between bony areas such as the knees and elbows. This makes it easier to manage postural support while helping reduce contact pressure between joints.

Surface Comfort and Moisture Management

The mattress is designed to help manage moisture at the surface, supporting a drier and more comfortable bed environment over time. This helps improve comfort during extended bed use while maintaining support in the air cells.

Who This Mattress Is Best Suited For

The Optima Turn is best suited for users who need regular turning and for family caregivers looking for a more manageable way to provide pressure relief at home. It is especially valuable when manual turning has become physically demanding, disruptive overnight, or difficult to keep consistent.

Important Notice: Due to health and hygiene regulations, this product is non-returnable. We recommend verifying the dimensions and specifications before purchase to ensure it meets your needs.

Specifications

Mattress
Maximum Patient Weight 397 lbs
Dimensions 78.7" L x 33.5/35.5" W x 5" D (with 10" side bolster)
Cell Height 21 x 13 cm (5" cells), 10" side bolster
Weight 27.5 lbs
Top Cover Material 4-way stretch PU, polyester cover with welded seams
Cell Material TPU
Pump
Dimensions 13.4" L x 6.5" W x 10.2" H
Weight 9.9 lbs
Case Material Fire-retardant ABS
Supply Voltage 220 - 240 V / 50 Hz, 110 - 120 V / 60 Hz
Operating Cycle 10 / 15 / 20 / 25 minutes
Additional Info
Pump Water-resistant standards (IP21)
Mattress Complies with flame-retardant standards (EN597-1, EN597-2), RoHS, WEEE
Documents
Warranty Information

The Wellell Optima Turn Lateral Rotation Pressure Relief Mattress comes with a 2-year warranty.

Product Video

Authorized Dealer

Wellell Authorized Dealer

Wellell Manufacturer's Product Warranty


Most products on our Wellell website come with a 12-month warranty against manufacturing defects. Check individual product listings for specific warranty details. If a defect occurs during the warranty period due to manufacturing issues, Wellell will provide replacement parts at no cost. Some manufacturers offer longer warranties, while others have shorter terms for certain items like batteries. Please note that wear and tear items and consumables are not covered by the warranty.

Order Processing

Once your order is placed, you will receive a confirmation email acknowledging receipt of your order.

Orders are fulfilled directly through our authorized manufacturer partners to ensure you receive the newest production inventory.

If an item is temporarily unavailable, we will contact you promptly with updated availability and options. At that time, you may choose to proceed with the revised timeline or cancel for a full refund.

If you confirm that you wish to proceed, the order becomes a confirmed backorder. Once we commit funds with the supplier to reserve inventory specifically for your order, it cannot be cancelled.

You will receive email updates throughout the process, including tracking details once your order ships.

Cancellations within 24 hours may be approved at our discretion if the order has not yet been placed with the supplier or shipped.

Returns

Eligible products may be returned within 7 days of delivery with prior return authorization.

Approved returns may be subject to:

  • A 25% restocking fee
  • Non-refundable outbound shipping charges
  • Non-refundable white-glove delivery charges (if applicable)
  • Return shipping costs paid by the customer

Returned items must be unused, in original packaging, and include all parts, accessories, manuals, and documentation.

Return requests submitted after 7 days of delivery may not be eligible for approval at our discretion.

To request a return authorization, please contact:
support@firstclassmobility.com

Pre-Orders & Backorders

Some products may require advance reservation to secure manufacturer inventory.

Pre-orders and confirmed backorders are paid in full at the time of purchase. Once inventory is reserved and funds are committed with the supplier, these orders cannot be cancelled.

Estimated shipping timelines are provided in good faith. Delays may occur due to manufacturing schedules, supplier availability, or freight logistics.

Any exception granted is at our sole discretion and may be subject to a cancellation and restocking fee.

Final Sale Items

Due to hygiene, safety, or manufacturer restrictions, the following items are non-returnable:

  • Beds and mattresses

  • Batteries and chargers

  • All lifts (residential, vehicle, and patient lifts)

  • Lift chairs, geri chairs, and patient room chairs

  • Wheelchair cushions, support surfaces, and slings

  • Mobility and Lift accessories 

  • Red light therapy devices

  • All products sold under the brand Discover Your Mobility

View the full list of non-returnable brands here 

Non-Returnable Accessories

Accessories are final sale and are not eligible for return or refund unless they arrive damaged, defective, or were shipped in error.

For purposes of this policy, an accessory is any optional add-on, enhancement, replacement component, comfort item, positioning aid, storage item, battery, charger, or similar product designed for use with a primary piece of durable medical equipment.

Examples include, but are not limited to:

  • Spare batteries
  • Chargers
  • Cup holders
  • Storage bags
  • Seat cushions
  • Positioning supports
  • Travel covers
  • Replacement parts
  • Other optional add-ons and upgrades

Defective, Damaged & Warranty Claims

Customers must inspect all products upon delivery. Any damage, defects, missing parts, or operational issues must be reported within 24 hours of delivery.

For approved warranty claims, manufacturers may provide troubleshooting, replacement parts, repair service, batteries, or replacement units under the applicable manufacturer warranty.

Replacement units are not guaranteed to ship immediately and may require troubleshooting, manufacturer approval, return inspection, and/or parts availability before processing.

Products designated as Final Sale or Non-Returnable are covered by the applicable manufacturer warranty process for defects or operational issues. Refunds are generally not available while the manufacturer is actively providing troubleshooting, repair, replacement parts, battery replacement, or replacement solutions under the warranty process.

Where warranty support or a replacement solution has already been provided or offered, the order may not qualify for a return or refund.

Damage or defects reported after 24 hours of delivery may not qualify for replacement, refund, or claim approval.

Missed Deliveries, Refused Shipments & Incorrect Addresses

Freight and large-item deliveries are scheduled to the address provided at checkout. Please ensure all delivery details are accurate before submitting your order.

If an order is refused at delivery or returned to the sender, a 25% restocking fee will apply, and all outbound and return shipping costs will be the customer’s responsibility.

If an incorrect or incomplete address is provided and the shipment requires re-delivery, address correction, or is returned to the sender, the customer is responsible for any additional shipping, freight, storage, or re-delivery fees charged by the carrier.

Warranty

All products are covered by the manufacturer’s warranty, which varies by brand and product.

We are happy to assist you with documentation, proof of purchase, and guidance throughout the warranty process. Warranty service, repairs, and replacements are handled directly by the manufacturer in accordance with their terms and coverage.

After the return period has passed, any repair or replacement requests will be subject to the manufacturer’s warranty policy and may require return of the defective item for inspection.

Payment Disputes

If you experience any issue with your order, please contact us directly so we can resolve it as quickly as possible.

In the event of a payment dispute, we may provide order records, communication history, and this policy to the payment provider for review.

Agreement

By placing an order with FirstClassMobility.com, you agree to the terms outlined in this Refund & Return Policy, including applicable restocking fees, shipping charges, and final sale exclusions.

Product specifications are provided by manufacturers as general guidance. Actual measurements and performance may vary slightly due to production tolerances, optional accessories, or model updates.

Wellell Optima Prone FAQ's

What is the purpose of the Optima Prone system?

The Optima Prone is a specialized pressure-reducing support surface designed to prevent pressure injuries, optimize workflow, reduce clinical workload, and improve patient outcomes during prone position ventilation.

How does the Shoulder Lifting Mode benefit patients and caregivers?

The Shoulder Lifting Mode relieves muscle hyperextension and stress in the shoulder area by offering two adjustable angles. It also supports head repositioning by lifting the shoulders, reducing caregiver workload, and minimizing the risk of airway tubing obstructions.

How does Optima Prone protect the patient’s face and ears?

The patented air cell design prevents pressure sores and injuries on sensitive areas like the face and ears during prone positioning.

Can head repositioning be performed by a single caregiver?

Yes, head repositioning can be completed by one caregiver. The system mechanically supports the shoulders and creates space for the chin, simplifying the process and ensuring safety.

What measures does Optima Prone take to reduce infection risks?

The top cover is made with welded seams to prevent fluid ingress, reducing the risk of contamination and infection.

How does the system handle tubing management?

Customizable airflow and individual air cell adjustments allow caregivers to organize and manage tubing effectively, minimizing the risk of obstructions.

What safety features are included in emergencies?

The system includes a CPR knob that allows for quick mattress deflation during emergencies.

What are the key features of the top cover material?

The 4-way stretch top cover offers low shear, low friction, vapor permeability, and moisture protection, ensuring optimal immersion and envelopment for the patient.

What certifications and compliance standards does Optima Prone meet?
  • Pump: Water-resistant standards (IP21)
  • Mattress: Flame-retardant standards (EN597-1, EN597-2)
  • Environmentally compliant with RoHS and WEEE standards.

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare