Skip to content

Save $100 on All Orders Over $1000! Use Code: MOBILITY100 at Checkout.

Free Shipping Within the 48 Contiguous States. (exclusions may apply)

Ships in 1-2 Business Days from Baldwin Park, CA

ObboMed OB-1650 StandardAir Mattress - Alternating Pressure Ulcer Prevention Mattress with Low Air Loss Air

SKU OB-1650
by ObboMed
Save 49% Save 49%
Original price $3,950.00
Original price $3,950.00 - Original price $3,950.00
Original price $3,950.00
Current price $1,998.00
$1,998.00 - $1,998.00
Current price $1,998.00

Lowest Prices Guaranteed

Free Shipping US

No Sales Tax


Secure Payments

OB-1650 StandardAir: Alternating Pressure Ulcer Prevention Mattress with Low Air Loss

The ObboMed OB-1650 StandardAir™ Mattress helps prevent bedsores and skin breakdown in patients who spend extended periods in bed. Its alternating air pockets inflate and deflate in cycles to redistribute body weight, reducing continuous pressure on the back, hips, and heels while improving blood flow to these areas.

The built-in low air loss system directs a gentle stream of air across the mattress surface to control heat and moisture, helping keep the skin dry and lowering the risk of irritation and infection. Constructed with reinforced medical-grade materials, the mattress maintains consistent pressure support for patients weighing up to 450 lbs, ensuring stable positioning and effective pressure relief in both hospital and home environments.

Safety and Positioning Support

Soft inflatable guardrails cushion against falls, while the mattress can sink up to 4 inches (paired with 4-inch guardrails for an 8-inch barrier) to keep patients centered during rotation. The mattress supports 15° self-lateral rotation and 25° left/right/auto rotation, with up to 40° of movement when combined. This helps improve comfort, support lung function, and assist with phlegm clearance. 

In a sitting posture, the Fowler Seating Support increases firmness under the seat and torso (by about 30%) to prevent the patient from sinking downward.

Note: Bed Frame, Bedpan, Shampoo are Not Included

OB-1650 StandardAir: Alternating Pressure Ulcer Prevention Mattress with Low Air Loss

ObboMed OB-1650 Control Panel/Pump Functions


OB-1650 StandardAir Mattress Features


💡 Note: The videos shown may display the automatic (one-touch) “Easy Go” system found on higher models (OB-2650 / OB-3650).

The OB-1650 provides manual ‘Easy Go’ Bedpan and Shampoo functions through a Quick-Release Valve system. The caregiver manually deflates and reinflates the mattress section to create space for a bedpan or shampoo basin.

Patented “Easy Go” Bedpan Function (Manual)

The caregiver uses the quick-release valve to deflate four air cells under the hips in about 20 seconds, creating a recessed space for a bedpan without moving the patient. After use, closing the valve reinflates the mattress.
(Bedpan not included.)

Patented “Easy Go” Shampoo Function (Manual)

Using the quick-release valve at the head section, the caregiver can deflate part of the mattress in about 20 seconds for a shampoo basin. Closing the valve restores the mattress to normal.
(Shampoo basin not included.)

Patented Inflatable Air-Filled Guardrails

The 4-inch inflatable guardrails use quick-release valves for fast inflation and deflation. They provide soft, cushioned protection against falls and bruises, offering a safer alternative to metal side rails while still allowing easy caregiver access.

Multiple Rotation Angles

The mattress supports 15° self-lateral rotation and 25° left/right/auto rotation, with up to 40° of movement when combined., these functions allow up to 40° of movement, which helps improve comfort, support lung function, and assist with phlegm clearance.

15° Self-Lateral Rotation & Sinking Feature

Special air cells gently inflate and deflate to create a 15° wave-like self-rotation, which helps redistribute pressure and improve circulation.
Sinking Feature with Centralization:
The sinking feature lowers the mattress by up to 4 inches, working with the 4-inch guardrails to form an 8-inch deep soft barrier that keeps patients safely centered during rotation.

Fowler & Seating Function

When the head of the bed is raised, the Fowler Seating Support boosts firmness under the seat and torso areas by about 30%. This prevents “bottoming out,” helps maintain posture, and reduces the risk of pressure injuries while seated upright.

Comfort-Focused True Low Air Loss (LAL) Therapy

The built-in fan delivers 15 LPM airflow beneath the cover. This reduces heat and moisture, keeping the skin cool and dry to lower the risk of pressure ulcers (Stage 1–4).


Cover Features


  • Designed to reduce skin friction and shearing

  • Vapor-permeable cover that removes moisture through airflow

  • Perspiration escapes through the cover surface and bed edges

  • Antimicrobial, liquid-resistant, and fireproof material

  • Free from latex, lead, and mercury

  • Low Air Loss system reduces humidity under the patient while removing moisture and heat

  • Air cells made of TPU and nylon, sealed with ultrasonic welding for durability

  • Liquid-proof and machine washable

Important Notice: Due to health and hygiene regulations, this product is non-returnable.   We recommend verifying the dimensions and specifications before purchase to ensure it meets your needs.


Documents



OB-1650 Mattress Specifications


Functions
Functions Alternating Pressure, Easy-Go Bedpan and Shampoo, 15° Self-lateral Rotation, 25° Right/Left/Auto Rotation, Low Air Loss Therapy (up to 15 LPM), Fowler/Seating Mode, Static Mode, Max-Inflate (Auto Firm), Easy Go” Bedpan Function, Easy Go” Shampoo Basin Function
Rotation Angles 15, 25, and 40 Degrees
Alternating Cycle Time 10, 20, 30, and 40 Minutes
Rotation Circle 10, 20, 30, 40, 60, 90, and 120 Minutes
Dimensions & Weight
Mattress Dimensions 80″L x 36″W x 7-11″H
Weight Capacity 450lbs
Mattress Weight 22lbs
Control Unit Weight 15.5lbs
Unit Package Dimensions 19.3″L x 16.9″W x 26.4″H
Unit Package Weight 41.7lbs
Pump & Air Flow
Pump 30 LPM
Low Air Loss (LAL) 15 LPM
Package Contents
Control unit 1 Piece
Mattress body 1 Piece
Power cord, 14 ft (427 cm) = 168.11 inches 1 Piece
Side spare filter foam 3 Pieces
Back spare filter foam 3 Pieces
Spare safety fuse, 125V/4A 2 Pieces
User Guide 1 Piece

Warranty


  • The ObboMed OB-1650 StandardAir Mattress comes with  a warranty of 1 Year on Top Cover, 2 Years on Control Unit and Mattress.

ObboMed Authorized Dealer

Warranty Information

The ObboMed OB-1650 StandardAir Mattress comes with  a warranty of 1 Year on Top Cover, 2 Years on Control Unit and Mattress.

Order Processing

Once your order is placed, you will receive a confirmation email acknowledging receipt of your order.

Orders are fulfilled directly through our authorized manufacturer partners to ensure you receive the newest production inventory.

If an item is temporarily unavailable, we will contact you promptly with updated availability and options. At that time, you may choose to proceed with the revised timeline or cancel for a full refund.

If you confirm that you wish to proceed, the order becomes a confirmed backorder. Once we commit funds with the supplier to reserve inventory specifically for your order, it cannot be cancelled.

You will receive email updates throughout the process, including tracking details once your order ships.

Cancellations within 24 hours may be approved at our discretion if the order has not yet been placed with the supplier or shipped.

Returns

Returns are accepted within 7 days of delivery for eligible products.

Approved returns are subject to:

  • A 25% restocking fee

  • Non-refundable outbound shipping

  • Non-refundable white-glove delivery charges (if applicable)

After 7 days, and up to 14 days from delivery, eligible products may be exchanged only.

After 14 days, all sales are considered final.

Returned items must be unused, in original packaging, and include all components and documentation. Return shipping costs are the customer’s responsibility.

To request a return, please email:
support@firstclassmobility.com

 

Pre-Orders & Backorders

Some products may require advance reservation to secure manufacturer inventory.

Pre-orders and confirmed backorders are paid in full at the time of purchase. Once inventory is reserved and funds are committed with the supplier, these orders cannot be cancelled.

Estimated shipping timelines are provided in good faith. Delays may occur due to manufacturing schedules, supplier availability, or freight logistics.

Any exception granted is at our sole discretion and may be subject to a cancellation and restocking fee.

Final Sale Items

Due to hygiene, safety, or manufacturer restrictions, the following items are non-returnable:

  • Beds and mattresses

  • Batteries and chargers

  • All lifts (residential, vehicle, and patient lifts)

  • Lift chairs, geri chairs, and patient room chairs

  • Wheelchair cushions, support surfaces, and slings

  • Mobility accessories

  • Red light therapy devices

  • All products sold under the brand Discover Your Mobility

View the full list of non-returnable brands here .

Defective or Damaged Items

If an item arrives defective or damaged, the manufacturer will offer a replacement at no cost. Issues must be reported within 24 hours of delivery.

A replacement requires the defective item to be returned before a new unit is shipped. A prepaid return label will be provided for approved claims.

If you decline a replacement and request a return instead, the request will be handled under the standard return policy, including a 25% restocking fee and non-refundable shipping costs.

Damage not reported within 24 hours may not be eligible for a claim.

Missed Deliveries, Refused Shipments & Incorrect Addresses

Freight and large-item deliveries are scheduled to the address provided at checkout. Please ensure all delivery details are accurate before submitting your order.

If an order is refused at delivery or returned to the sender, a 25% restocking fee will apply, and all outbound and return shipping costs will be the customer’s responsibility.

If an incorrect or incomplete address is provided and the shipment requires re-delivery, address correction, or is returned to the sender, the customer is responsible for any additional shipping, freight, storage, or re-delivery fees charged by the carrier.

Warranty

All products are covered by the manufacturer’s warranty, which varies by brand and product.

We are happy to assist you with documentation, proof of purchase, and guidance throughout the warranty process. Warranty service, repairs, and replacements are handled directly by the manufacturer in accordance with their terms and coverage.

After the return period has passed, any repair or replacement requests will be subject to the manufacturer’s warranty policy and may require return of the defective item for inspection.

Payment Disputes

If you experience any issue with your order, please contact us directly so we can resolve it as quickly as possible.

In the event of a payment dispute, we may provide order records, communication history, and this policy to the payment provider for review.

Agreement

By placing an order with FirstClassMobility.com, you agree to the terms outlined in this Refund & Return Policy, including applicable restocking fees, shipping charges, and final sale exclusions.

Product specifications are provided by manufacturers as general guidance. Actual measurements and performance may vary slightly due to production tolerances, optional accessories, or model updates.

Frequently Ask Question

What is the OB-1650 StandardAir™ Mattress designed for?

The OB-1650 is a medical air mattress designed to prevent and treat pressure ulcers (Stages 1–4). It provides alternating pressure, low air loss therapy, rotation features, and seating support to enhance comfort and safety for patients who remain in bed for long periods.

What makes the OB-1650 different from the OB-1620?

Unlike the OB-1620, the OB-1650 includes manual “Easy-Go” Bedpan and Shampoo functions as well as inflatable guardrails for added safety. These features make daily care and hygiene easier while minimizing the risk of falls and injury.

How does the “Easy-Go” Bedpan function work?

The caregiver uses the manual Quick-Release Valve to deflate four air cells under the hips within about 20 seconds, creating a recessed space for a bedpan. After use, closing the valve reinflates the mattress. (Bedpan not included.)

How does the “Easy-Go” Shampoo function help caregivers?

By deflating a section of the mattress near the head with the Quick-Release Valve, space is created for a shampoo basin. This allows caregivers to wash a patient’s hair without lifting or moving them. (Shampoo basin not included.)

Are the inflatable guardrails safe and comfortable?

Yes. The 4-inch inflatable air-filled guardrails provide cushioned protection against falls and bruises, making them a safer alternative to metal side rails. Combined with the sinking feature, they help keep patients securely centered in the bed.

What rotation and positioning options does the OB-1650 provide?

The mattress supports 15° self-lateral rotation, 25° programmed side-to-side rotation, and up to 40° movement when combined. These features reduce pressure, improve circulation, support lung function, and aid phlegm clearance.

How does the Low Air Loss (LAL) system work?

The built-in fan delivers 15 liters of airflow per minute under the cover, which helps reduce heat, humidity, and moisture buildup. This creates a cooler, drier environment that lowers the risk of skin breakdown.

What are the OB-1650 mattress dimensions and weight capacity?
  • Mattress Dimensions: 80″L x 36″W x 7–11″H
  • Weight Capacity: 450 lbs
  • Mattress Weight: 22 lbs
  • Control Unit Weight: 15.5 lbs

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare