The Protekt® Aire 5000DX by Proactive Medical is a low air loss and alternating pressure mattress system designed for comfort and skin protection. Its digital pump features Auto Compressor Sleep Technology (ACST), which extends pump life by shutting off the compressor once the desired pressure is reached. The pump offers adjustable weight settings, a preset 10-minute alternating cycle, and a static function for safe patient transfers.
The mattress includes a 5-inch air layer with a 3-inch densified fiber base for added support during power failures. With a weight capacity of 400 lbs and dimensions of 80”L x 36”W x 8”H, it is suitable for various patient needs. Optional raised side rails provide extra safety, making it a reliable choice for effective pressure therapy and patient care.
The Protekt® Aire 5000DX helps patients by providing advanced pressure redistribution and moisture management, which are essential for preventing and managing pressure injuries. The low air loss feature keeps the patient’s skin cool and dry, reducing the risk of skin breakdown, while the alternating pressure therapy relieves pressure on vulnerable areas of the body. The static function ensures stability during transfers, making it safer and more comfortable for patients to get in and out of bed.

Important Notice: Due to health and hygiene regulations, this product is non-returnable. We recommend verifying the dimensions and specifications before purchase to ensure it meets your needs.
PDAC Coding Verification Letter
| Specification | Details |
|---|---|
| Power Supply | 120 V, 50Hz |
| Air Output | 8 LPM |
| Pressure Range | 20 mmHg - 50 mmHg |
| Cycle Time | 10 min. |
| Fuse | 250 V, 1 A |
| Pump Dimensions | 10.6" x 6" x 4" |
| Pump Weight | 3.5 lbs. |
| Mattress Dimensions |
80"L x 36"W x 8"H |
| Mattress Construction | Top Cover: Quilted Nylon/ PU Air Cells: 17 ea, Nylon/ PVC, 5"H Bottom Cover: Nylon/ PVC w/ 3"H Foam |
| Weight Capacity | 400 lbs. |
Once your order is placed, you will receive a confirmation email acknowledging receipt of your order.
Orders are fulfilled directly through our authorized manufacturer partners to ensure you receive the newest production inventory.
If an item is temporarily unavailable, we will contact you promptly with updated availability and options. At that time, you may choose to proceed with the revised timeline or cancel for a full refund.
If you confirm that you wish to proceed, the order becomes a confirmed backorder. Once we commit funds with the supplier to reserve inventory specifically for your order, it cannot be cancelled.
You will receive email updates throughout the process, including tracking details once your order ships.
Cancellations within 24 hours may be approved at our discretion if the order has not yet been placed with the supplier or shipped.
Returns are accepted within 7 days of delivery for eligible products.
Approved returns are subject to:
A 25% restocking fee
Non-refundable outbound shipping
Non-refundable white-glove delivery charges (if applicable)
After 7 days, and up to 14 days from delivery, eligible products may be exchanged only.
After 14 days, all sales are considered final.
Returned items must be unused, in original packaging, and include all components and documentation. Return shipping costs are the customer’s responsibility.
To request a return, please email:
support@firstclassmobility.com
Some products may require advance reservation to secure manufacturer inventory.
Pre-orders and confirmed backorders are paid in full at the time of purchase. Once inventory is reserved and funds are committed with the supplier, these orders cannot be cancelled.
Estimated shipping timelines are provided in good faith. Delays may occur due to manufacturing schedules, supplier availability, or freight logistics.
Any exception granted is at our sole discretion and may be subject to a cancellation and restocking fee.
Due to hygiene, safety, or manufacturer restrictions, the following items are non-returnable:
Beds and mattresses
Batteries and chargers
All lifts (residential, vehicle, and patient lifts)
Lift chairs, geri chairs, and patient room chairs
Wheelchair cushions, support surfaces, and slings
Mobility accessories
Red light therapy devices
All products sold under the brand Discover Your Mobility
View the full list of non-returnable brands here .
If an item arrives defective or damaged, the manufacturer will offer a replacement at no cost. Issues must be reported within 24 hours of delivery.
A replacement requires the defective item to be returned before a new unit is shipped. A prepaid return label will be provided for approved claims.
If you decline a replacement and request a return instead, the request will be handled under the standard return policy, including a 25% restocking fee and non-refundable shipping costs.
Damage not reported within 24 hours may not be eligible for a claim.
Freight and large-item deliveries are scheduled to the address provided at checkout. Please ensure all delivery details are accurate before submitting your order.
If an order is refused at delivery or returned to the sender, a 25% restocking fee will apply, and all outbound and return shipping costs will be the customer’s responsibility.
If an incorrect or incomplete address is provided and the shipment requires re-delivery, address correction, or is returned to the sender, the customer is responsible for any additional shipping, freight, storage, or re-delivery fees charged by the carrier.
All products are covered by the manufacturer’s warranty, which varies by brand and product.
We are happy to assist you with documentation, proof of purchase, and guidance throughout the warranty process. Warranty service, repairs, and replacements are handled directly by the manufacturer in accordance with their terms and coverage.
After the return period has passed, any repair or replacement requests will be subject to the manufacturer’s warranty policy and may require return of the defective item for inspection.
If you experience any issue with your order, please contact us directly so we can resolve it as quickly as possible.
In the event of a payment dispute, we may provide order records, communication history, and this policy to the payment provider for review.
By placing an order with FirstClassMobility.com, you agree to the terms outlined in this Refund & Return Policy, including applicable restocking fees, shipping charges, and final sale exclusions.
Product specifications are provided by manufacturers as general guidance. Actual measurements and performance may vary slightly due to production tolerances, optional accessories, or model updates.
The mattress system supports a weight capacity of up to 400 lbs.
The system features Auto Compressor Sleep Technology (ACST), which turns off the compressor once the desired pressure is reached, extending pump life.
The mattress system provides low air loss and alternating pressure therapies, which work together to prevent and manage pressure injuries.
The pump has adjustable weight settings, allowing clinicians to customize the pressure according to each patient’s specific therapeutic needs.
The system includes a preset 10-minute alternating cycle for pressure relief and comfort.
Yes, the system has a static function that ensures stability during patient transfers, making it safer and easier for patients to get in and out of bed.
Yes, it includes an audio/visual low-pressure alarm to alert caregivers in case of compromised airflow.
The mattress includes a 5-inch air layer with a 3-inch densified fiber base, which ensures solid support in the event of a power failure.
The mattress includes 18 laser holes that promote air circulation, keeping the patient cool and dry.
Yes, the system offers optional raised foam side rails for added patient security.