Protekt Aire 6000 LAL/AP Mattress System
Lowest Prices Guaranteed
Free Shipping US
No Sales Tax
Lowest Prices Guaranteed
Free Shipping US
No Sales Tax
The Proactive Medical Protekt Aire 6000 Mattress System by Proactive Medical is the preferred choice for clinicians treating pressure ulcers, featuring advanced specifications and features for superior patient care. With a 450 lbs weight capacity, this system includes a deluxe digital pump offering dual therapies: low air loss and alternating pressure. Available in 80 - 84 inches Length with or without foam side rail option.
The user-friendly LED touch panel provides access to four alternating cycles (10, 15, 20, and 25 minutes), while key features such as a seat-inflate function, auto firm mode, and static mode enhance patient protection and support. The pump is equipped with three alarms for low pressure, power failure, and alternating failure to ensure patient safety.

The mattress has a unique cell-on-cell design with a one-way valve that retains air in the lower 4" of cells during power outages. Eighteen laser holes improve air circulation, keeping the patient cool and dry. The fluid-resistant, anti-microbial/anti-bacterial nylon top cover is quilted for added comfort, and the pillow top feature minimizes head and neck movement during alternating pressure cycles.
The Protekt Aire 6000 Mattress System is designed for optimal comfort and safety, making it an essential solution for effective pressure ulcer management. Recognized under Medicare code E0277, this system offers innovative and reliable therapeutic benefits.

Dual Therapy Modes (Low Air Loss & Alternating Pressure) – Provides effective pressure redistribution and moisture control for enhanced patient comfort and pressure ulcer prevention.
Customizable Alternating Cycle Times (10, 15, 20, & 25 Minutes) – Allows clinicians to adjust therapy to meet individual patient needs.
Seat-Inflate Feature – Offers extra support in the fowler position, reducing pressure on vulnerable areas.
Auto Firm Mode – Quickly inflates the mattress for easier patient transfer or repositioning.
Static Mode – Provides firm support for patient ingress, egress, or side-edge seating.
Audible & Visual Alarms (Low Pressure, Power Failure, Alternating Failure) – Alerts caregivers to system issues, ensuring patient safety.
Cell-On-Cell Design – Maintains air in the lower cells during power failure, preventing bottoming out for continuous support.
18 Laser Holes for Air Circulation – Enhances breathability, keeping the patient cool and dry.
Fluid-Resistant, Quilted Nylon Top Cover – Protects against moisture while providing additional comfort.
Pillow Top Feature – Reduces unnecessary head and neck movement during alternating pressure cycles.
Available in 84” Length – Accommodates taller patients for better fit and support.
Optional Raised Side Rails – Adds an extra layer of safety by preventing accidental falls.
Important Notice: Due to health and hygiene regulations, this product is non-returnable. We recommend verifying the dimensions and specifications before purchase to ensure it meets your needs.
Protekt Aire 6000 Series Manual
Protekt Aire 6000 Mattress Guide
PDAC Coding Verification Letter
| Specification | Details |
|---|---|
| Power Supply | 120 V, 50 Hz, 1 A |
| Air Output | 8 LPM |
| Pressure Range | 20 mmHg - 55 mmHg |
| Cycle Time | 10, 15, 20 or 25 min. |
| Fuse | 250 V, 1 A |
| Pump Dimensions | 12.2" x 4.9" x 8.3" |
| Pump Weight | 5.5 lbs. |
| Mattress Dimensions |
80"L x 36"W x 8"H |
| Mattress Construction | Top Cover: Quilted Nylon/ PU Air Cells: 20 ea (80"L), Nylon/ PVC w/ Cell-on-Cell Base Bottom Cover: Nylon/ PVC |
| Weight Capacity | 450 lbs. |
Once your order is placed, you will receive a confirmation email acknowledging receipt of your order.
Orders are fulfilled directly through our authorized manufacturer partners to ensure you receive the newest production inventory.
If an item is temporarily unavailable, we will contact you promptly with updated availability and options. At that time, you may choose to proceed with the revised timeline or cancel for a full refund.
If you confirm that you wish to proceed, the order becomes a confirmed backorder. Once we commit funds with the supplier to reserve inventory specifically for your order, it cannot be cancelled.
You will receive email updates throughout the process, including tracking details once your order ships.
Cancellations within 24 hours may be approved at our discretion if the order has not yet been placed with the supplier or shipped.
Returns are accepted within 7 days of delivery for eligible products.
Approved returns are subject to:
A 25% restocking fee
Non-refundable outbound shipping
Non-refundable white-glove delivery charges (if applicable)
After 7 days, and up to 14 days from delivery, eligible products may be exchanged only.
After 14 days, all sales are considered final.
Returned items must be unused, in original packaging, and include all components and documentation. Return shipping costs are the customer’s responsibility.
To request a return, please email:
support@firstclassmobility.com
Some products may require advance reservation to secure manufacturer inventory.
Pre-orders and confirmed backorders are paid in full at the time of purchase. Once inventory is reserved and funds are committed with the supplier, these orders cannot be cancelled.
Estimated shipping timelines are provided in good faith. Delays may occur due to manufacturing schedules, supplier availability, or freight logistics.
Any exception granted is at our sole discretion and may be subject to a cancellation and restocking fee.
Due to hygiene, safety, or manufacturer restrictions, the following items are non-returnable:
Beds and mattresses
Batteries and chargers
All lifts (residential, vehicle, and patient lifts)
Lift chairs, geri chairs, and patient room chairs
Wheelchair cushions, support surfaces, and slings
Mobility accessories
Red light therapy devices
All products sold under the brand Discover Your Mobility
View the full list of non-returnable brands here .
If an item arrives defective or damaged, the manufacturer will offer a replacement at no cost. Issues must be reported within 24 hours of delivery.
A replacement requires the defective item to be returned before a new unit is shipped. A prepaid return label will be provided for approved claims.
If you decline a replacement and request a return instead, the request will be handled under the standard return policy, including a 25% restocking fee and non-refundable shipping costs.
Damage not reported within 24 hours may not be eligible for a claim.
Freight and large-item deliveries are scheduled to the address provided at checkout. Please ensure all delivery details are accurate before submitting your order.
If an order is refused at delivery or returned to the sender, a 25% restocking fee will apply, and all outbound and return shipping costs will be the customer’s responsibility.
If an incorrect or incomplete address is provided and the shipment requires re-delivery, address correction, or is returned to the sender, the customer is responsible for any additional shipping, freight, storage, or re-delivery fees charged by the carrier.
All products are covered by the manufacturer’s warranty, which varies by brand and product.
We are happy to assist you with documentation, proof of purchase, and guidance throughout the warranty process. Warranty service, repairs, and replacements are handled directly by the manufacturer in accordance with their terms and coverage.
After the return period has passed, any repair or replacement requests will be subject to the manufacturer’s warranty policy and may require return of the defective item for inspection.
If you experience any issue with your order, please contact us directly so we can resolve it as quickly as possible.
In the event of a payment dispute, we may provide order records, communication history, and this policy to the payment provider for review.
By placing an order with FirstClassMobility.com, you agree to the terms outlined in this Refund & Return Policy, including applicable restocking fees, shipping charges, and final sale exclusions.
Product specifications are provided by manufacturers as general guidance. Actual measurements and performance may vary slightly due to production tolerances, optional accessories, or model updates.
The mattress system supports a weight capacity of up to 450 lbs.
The system offers dual therapies: low air loss and alternating pressure to ensure effective pressure ulcer prevention and management.
The system features four customizable alternating cycle times: 10, 15, 20, and 25 minutes, allowing clinicians to adjust the therapy based on patient needs.
The seat-inflate function provides extra support for patients in the fowler position, reducing pressure on vulnerable areas.
Yes, the pump includes three audible and visual alarms: low pressure, power failure, and alternating failure, ensuring patient safety.
The mattress features a unique cell-on-cell design with a one-way valve that retains air in the lower cells during a power failure, preventing the mattress from bottoming out and ensuring continued support.
The 18 laser holes improve air circulation within the mattress, helping to keep the patient cool and dry, which is essential for preventing moisture buildup.
The top cover is made of fluid-resistant, anti-microbial, and anti-bacterial quilted nylon, offering added comfort and protection against moisture.
Yes, the mattress is available in both 80" and 84" lengths, providing options for taller patients.
Yes, the system comes with a 2-year non-prorated warranty for both the pump and the mattress.
{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}