The Protekt Aire 4600DXAB Low Air Loss/alternating pressure Mattress System by Proactive Medical offers advanced pressure relief and comfort. With its low air loss and alternating pressure therapies, helping to prevent and treat pressure ulcers. Designed for safety, it features raised side air bolsters to reduce roll-out risks and a center cut-out for easy entry and exit.
The cell-on-cell support base retains air in the lower cells during power failures for continuous support, while 18 laser holes enhance airflow to keep patients cool and dry. Its fluid-resistant stretch nylon cover and pillow top feature provide added stability and comfort. With a weight capacity of 400 lbs and dimensions of 36” x 80” x 8”.

The Protekt® Aire 4600DXAB Low Air Loss & Alternating Pressure Mattress System features the Protekt® Aire 4000DX Pump, designed for comfort and reliability. Its Auto Compressor Sleep Technology (ACST) shuts off the compressor once the desired pressure is reached, extending pump life.
Offering both low air loss and alternating pressure, it helps prevent pressure ulcers while providing customizable comfort with adjustable weight settings. A preset 10-minute alternating cycle ensures continuous pressure relief, while the static mode allows for safe patient transfers. For added safety, an audio/visual low-pressure alarm alerts caregivers if airflow is compromised. This durable pump enhances both patient care and mattress performance.

Auto Compressor Sleep Technology (ACST) – Extends the pump’s lifespan by shutting off the compressor once the desired pressure level is reached.
Dual Therapy System – Combines low air loss and alternating pressure to help prevent pressure ulcers and improve patient comfort.
Adjustable Weight Settings – Allows caregivers to customize pressure levels based on individual therapeutic needs.
Preset 10-Minute Alternating Cycle – Provides consistent pressure redistribution to reduce the risk of skin breakdown.
Static Function – Offers firm support for safe and easy patient transfers.
Audio/Visual Low-Pressure Alarm – Alerts caregivers if airflow is compromised, ensuring patient safety.
Durable Digital Pump Design – Built for long-lasting performance, enhancing both patient care and mattress longevity.
Important Notice: Due to health and hygiene regulations, this product is non-returnable. We recommend verifying the dimensions and specifications before purchase to ensure it meets your needs.
Protekt-Aire-4600DXAB Individual Brochure
Protekt-Aire-4600DXAB Product Manual
Protekt-Aire-4600DXAB Mattress Guide
| Specification | Details |
|---|---|
| Power Supply | 120 V, 50Hz |
| Air Output | 8 LPM |
| Pressure Range | 20 mmHg - 50 mmHg |
| Cycle Time | 10 min. |
| Fuse | 250 V, 1 A |
| Pump Dimensions | 10.6" x 6" x 4" |
| Pump Weight | 3.5 lbs. |
| Mattress Dimensions | 80"L x 36"W x 8"H |
| Mattress Construction | Top Cover: Quilted Nylon/ PU Air Cells: 20 ea (80"L), Nylon/ PVC w/ Cell-on-Cell Base 11"H Side Air Bolsters Bottom Cover: Nylon/ PVC |
| Weight Capacity | 400 lbs. |
Once your order is placed, you will receive a confirmation email acknowledging receipt of your order.
Orders are fulfilled directly through our authorized manufacturer partners to ensure you receive the newest production inventory.
If an item is temporarily unavailable, we will contact you promptly with updated availability and options. At that time, you may choose to proceed with the revised timeline or cancel for a full refund.
If you confirm that you wish to proceed, the order becomes a confirmed backorder. Once we commit funds with the supplier to reserve inventory specifically for your order, it cannot be cancelled.
You will receive email updates throughout the process, including tracking details once your order ships.
Cancellations within 24 hours may be approved at our discretion if the order has not yet been placed with the supplier or shipped.
Returns are accepted within 7 days of delivery for eligible products.
Approved returns are subject to:
A 25% restocking fee
Non-refundable outbound shipping
Non-refundable white-glove delivery charges (if applicable)
After 7 days, and up to 14 days from delivery, eligible products may be exchanged only.
After 14 days, all sales are considered final.
Returned items must be unused, in original packaging, and include all components and documentation. Return shipping costs are the customer’s responsibility.
To request a return, please email:
support@firstclassmobility.com
Some products may require advance reservation to secure manufacturer inventory.
Pre-orders and confirmed backorders are paid in full at the time of purchase. Once inventory is reserved and funds are committed with the supplier, these orders cannot be cancelled.
Estimated shipping timelines are provided in good faith. Delays may occur due to manufacturing schedules, supplier availability, or freight logistics.
Any exception granted is at our sole discretion and may be subject to a cancellation and restocking fee.
Due to hygiene, safety, or manufacturer restrictions, the following items are non-returnable:
Beds and mattresses
Batteries and chargers
All lifts (residential, vehicle, and patient lifts)
Lift chairs, geri chairs, and patient room chairs
Wheelchair cushions, support surfaces, and slings
Mobility accessories
Red light therapy devices
All products sold under the brand Discover Your Mobility
View the full list of non-returnable brands here .
If an item arrives defective or damaged, the manufacturer will offer a replacement at no cost. Issues must be reported within 24 hours of delivery.
A replacement requires the defective item to be returned before a new unit is shipped. A prepaid return label will be provided for approved claims.
If you decline a replacement and request a return instead, the request will be handled under the standard return policy, including a 25% restocking fee and non-refundable shipping costs.
Damage not reported within 24 hours may not be eligible for a claim.
Freight and large-item deliveries are scheduled to the address provided at checkout. Please ensure all delivery details are accurate before submitting your order.
If an order is refused at delivery or returned to the sender, a 25% restocking fee will apply, and all outbound and return shipping costs will be the customer’s responsibility.
If an incorrect or incomplete address is provided and the shipment requires re-delivery, address correction, or is returned to the sender, the customer is responsible for any additional shipping, freight, storage, or re-delivery fees charged by the carrier.
All products are covered by the manufacturer’s warranty, which varies by brand and product.
We are happy to assist you with documentation, proof of purchase, and guidance throughout the warranty process. Warranty service, repairs, and replacements are handled directly by the manufacturer in accordance with their terms and coverage.
After the return period has passed, any repair or replacement requests will be subject to the manufacturer’s warranty policy and may require return of the defective item for inspection.
If you experience any issue with your order, please contact us directly so we can resolve it as quickly as possible.
In the event of a payment dispute, we may provide order records, communication history, and this policy to the payment provider for review.
By placing an order with FirstClassMobility.com, you agree to the terms outlined in this Refund & Return Policy, including applicable restocking fees, shipping charges, and final sale exclusions.
Product specifications are provided by manufacturers as general guidance. Actual measurements and performance may vary slightly due to production tolerances, optional accessories, or model updates.
The mattress system supports up to 400 lbs, making it suitable for various patient needs.
The mattress measures 36” x 80” x 8”. No raised foam rails available on this mattress.
It offers low air loss and alternating pressure therapies to help reduce the risk of pressure ulcers and improve patient comfort.
The ACST feature automatically shuts off the compressor once the desired pressure level is reached, extending the pump’s lifespan and improving efficiency.
The cell-on-cell construction ensures air remains in the lower cells in case of a power failure, providing extra support and safety.
The pump has an audio/visual low-pressure alarm to alert caregivers if airflow is compromised.
The stretch nylon top cover is fluid-resistant and vapor permeable, helping to keep patients cool and dry while ensuring durability.
The static mode provides a firm surface for safe and easy patient transfers.
It includes a 2-year non-prorated warranty on both the mattress and pump.